FOUNDRY-SN-STACKING-MIB DEFINITIONS ::= BEGIN

IMPORTS
	MODULE-IDENTITY, OBJECT-TYPE, Integer32
	  FROM SNMPv2-SMI
	snSwitch
		FROM FOUNDRY-SN-SWITCH-GROUP-MIB
	MacAddress
	  FROM SNMPv2-TC
	DisplayString
	  FROM FOUNDRY-SN-AGENT-MIB
	InterfaceIndexOrZero
	  FROM IF-MIB;
snStacking MODULE-IDENTITY
    LAST-UPDATED "201006020000Z"  -- 04 June 2010
    ORGANIZATION "Brocade Communications Systems, Inc."
    CONTACT-INFO
             "Technical Support Center
              130 Holger Way,
              San Jose, CA  95134
              Email:  ipsupport@brocade.com
              Phone: 1-800-752-8061
              URL:  www.brocade.com"
    DESCRIPTION
	      "Management Information for stacking system
	       configuration and operational status.

              Copyright 1996-2010 Brocade Communications Systems, Inc.
              All rights reserved.
              This Brocade Communications Systems SNMP Management Information Base Specification
              embodies Brocade Communications Systems' confidential and proprietary
              intellectual property. Brocade Communications Systems retains all
              title and ownership in the Specification, including any revisions.

              This Specification is supplied AS IS, and Brocade Communications Systems makes
              no warranty, either express or implied, as to the use,
              operation, condition, or performance of the specification, and any unintended
              consequence it may on the user environment."

    REVISION        "201006020000Z"  -- 04 June 2010
    DESCRIPTION
        "Changed the ORGANIZATION, CONTACT-INFO and DESCRIPTION fields."
	REVISION     "200805050000Z" -- May 5, 2008
	DESCRIPTION
			""
   ::= { snSwitch 31}


--
-- Stacking system
--

snStackingGlobalObjects OBJECT IDENTIFIER ::= { snStacking 1 }
snStackingTableObjects  OBJECT IDENTIFIER ::= { snStacking 2 }

--
-- Stacking system Global Scalar Object Section
--

snStackingGlobalConfigState OBJECT-TYPE
	SYNTAX     INTEGER {
			  none(0),
			  enabled(1),
			  disabled(2)
			}
	MAX-ACCESS read-write
	STATUS     current
	DESCRIPTION
		"Configure stack state for stacking feature on the global level.
		 none: neutral, receive packets only
		 enable: stacking is enable, send and receive packets
		 disable: stacking is disable, No send and receive packets"
	::= { snStackingGlobalObjects 1}

snStackingGlobalMacAddress OBJECT-TYPE
	SYNTAX     MacAddress
	MAX-ACCESS read-write
	STATUS     current
	DESCRIPTION
		"Management MAC address of the stacking system.
		This is available to change management MAC address of stack
		for administrative purpose. It is strongly recommended that this
		command should be used with upmost caution to prevent duplicate
		MAC address and must reboot the system to take an effect.
		It is mutually exclusive from enabling the persistent MAC timer.
		Enter zero MAC address to remove the configured MAC address"
	::= { snStackingGlobalObjects 2 }

snStackingGlobalPersistentMacTimerState OBJECT-TYPE
	SYNTAX     INTEGER {
			  enabled(0),
			  disabled(1)
			}
	MAX-ACCESS read-write
	STATUS     current
	DESCRIPTION
		"Configure persistent MAC timer state for stacking feature on the global level.
		 enable: the persistent MAC timer is active and configured. The persistent MAC
					  timer is set as the default timer (60 minutes)
		 disable: deactivate the persistent MAC timer. It will stop the use of persistent MAC
					  address and use new active stack unit's base MAC address "
	::= { snStackingGlobalObjects 3}

snStackingGlobalPersistentMacTimer OBJECT-TYPE
	SYNTAX     Integer32
	MAX-ACCESS read-write
	STATUS     current
	DESCRIPTION
		"Persistent MAC timer in minutes for the stacking system
		Number of minutes to retain original active stack unit's base MAC address in event of
		active unit crash or removal. This timer is triggered when new active unit is elected.
		When timer expires, new active unit will change stacking MAC to its own base MAC
		address and advertise its own base MAC address to management VLAN to update the
		ARP table of peers. If you decide to use new active unit's MAC address, one must enter
		this timer again to reactivate the persistent MAC.
				  0 - keep it forever.
				  5  to 6000 - valid value range.
				  60 - default value."
	::= { snStackingGlobalObjects 4 }

snStackingGlobalTopology OBJECT-TYPE
	SYNTAX     INTEGER {
			  other(1),
				 chain(2),
				 ring(3),
				 standalone(4)
			   }
	MAX-ACCESS read-only
	STATUS     current
	DESCRIPTION
		"The topology of the stacking system "
	::= { snStackingGlobalObjects 5 }

snStackingGlobalMode OBJECT-TYPE
	SYNTAX     INTEGER {
			stackingMode(1),
			nonStackingMode(2)
			}
	MAX-ACCESS read-only
	STATUS     current
	DESCRIPTION
		"The stacking mode of the system. 
		stackingMode: the system has been installed STK EEPROM, and it is in stacking mode.
		nonStackingMode:the system has not been installed STK EEPROM, and it is not in stacking mode.
		"
	::= { snStackingGlobalObjects 6 }

snStackingGlobalMixedMode OBJECT-TYPE
	SYNTAX     INTEGER {
			mixedStackingMode(1),
			classicStackingMode(2)
			}
	MAX-ACCESS read-only
	STATUS     current
	DESCRIPTION
		"The mixed stacking mode of the system. 
		mixedStackingMode: the system is in mixed stacking mode (heterogeneous stacking).
		classicStackingMode: the system is not in mixed stacking mode (homogeneous stacking).
		"
	::= { snStackingGlobalObjects 7 }
 
snStackingGlobalMaxUnitNumber OBJECT-TYPE
	SYNTAX     Integer32
	MAX-ACCESS read-only
	STATUS     current
	DESCRIPTION
		"The max number of units in the stacking system. 1 as default value for no-stacking device"
	::= { snStackingGlobalObjects 8 }

snStackingGlobalHighestPriority OBJECT-TYPE
	SYNTAX     Integer32
	MAX-ACCESS read-only
	STATUS     current
	DESCRIPTION
		"The highest stack priority that can be configured in the stacking system. 0 as default value 
		for no-stacking device"
	::= { snStackingGlobalObjects 9 }


--
-- Stacking system Table Object Section
--

--
-- Stacking configuration unit Table
-- Use this table to display and configure stacking related information for each unit
--

snStackingConfigUnitTable OBJECT-TYPE
	SYNTAX     SEQUENCE OF SnStackingConfigUnitEntry
	MAX-ACCESS not-accessible
	STATUS     current
	DESCRIPTION
		"Stacking configuration unit table."
	::= { snStackingTableObjects 1 }

snStackingConfigUnitEntry OBJECT-TYPE
	SYNTAX     SnStackingConfigUnitEntry
	MAX-ACCESS not-accessible
	STATUS     current
	DESCRIPTION
		"An entry in the stacking configuration table."
	INDEX { snStackingConfigUnitIndex }
	::= { snStackingConfigUnitTable 1 }

SnStackingConfigUnitEntry ::= SEQUENCE {
	snStackingConfigUnitIndex                          Integer32,
	snStackingConfigUnitPriority                       Integer32,
	snStackingConfigUnitConfigStackPort          InterfaceIndexOrZero,
	snStackingConfigUnitRowStatus                  INTEGER,
	snStackingConfigUnitType                          DisplayString,
	snStackingConfigUnitState                          INTEGER,
	snStackingConfigUnitStackPort1                  InterfaceIndexOrZero,
	snStackingConfigUnitStackPort2                  InterfaceIndexOrZero,
	snStackingConfigUnitConnectPort1              InterfaceIndexOrZero,
	snStackingConfigUnitConnectPort2              InterfaceIndexOrZero
}

snStackingConfigUnitIndex OBJECT-TYPE
	SYNTAX Integer32
	MAX-ACCESS not-accessible
	STATUS     current
	DESCRIPTION
		"The stacking unit Id"
	::= { snStackingConfigUnitEntry 1 }

 snStackingConfigUnitPriority OBJECT-TYPE
	SYNTAX     Integer32 (0..255)
	MAX-ACCESS read-write
	STATUS     current
	DESCRIPTION
		"The priority in Active/backup eclection."
	::= { snStackingConfigUnitEntry 2 }

 snStackingConfigUnitConfigStackPort OBJECT-TYPE
	SYNTAX		InterfaceIndexOrZero
	MAX-ACCESS  read-write
	STATUS     current
	DESCRIPTION
		"The IfIndex for the configured stacking port. If no
		stacking port is configured, it will be displayed zero
		and the first  two 10G ports as the default stacking ports.
		Enter zero to remove the configured stacking port. "
	::= { snStackingConfigUnitEntry 3 }

snStackingConfigUnitRowStatus OBJECT-TYPE
	SYNTAX     INTEGER {
				 other(1),
				 valid(2),
				 delete(3)
		  --       create(4)
			   }
	MAX-ACCESS read-write
	STATUS     current
	DESCRIPTION
			"This object is used to delete row in the
			table and control if they are used. The values that
			can be written are:
			delete(3)...deletes the row

			If the row exists, then a SET with value of create(4)
			returns error 'wrongValue'. Deleted rows go away immediately.
			The following values can be returned on reads:
			noSuchName...no such row
			other(1).....some other cases
			valid(2)....the row exists and is valid"
	::= { snStackingConfigUnitEntry 4 }


snStackingConfigUnitType OBJECT-TYPE
	SYNTAX	DisplayString
	MAX-ACCESS read-only
	   STATUS     current
	DESCRIPTION
		"A description of the configured/active system type for each unit."
	::= { snStackingConfigUnitEntry 5 }

snStackingConfigUnitState OBJECT-TYPE
	SYNTAX     INTEGER {
				 local(1),
				 remote(2),
				 reserved(3),
				 empty(4)
			   }
	MAX-ACCESS read-only
	STATUS     current
	DESCRIPTION
		"A state for each unit "
	::= { snStackingConfigUnitEntry 6 }

 snStackingConfigUnitStackPort1 OBJECT-TYPE
	SYNTAX		InterfaceIndexOrZero
	MAX-ACCESS read-only
	STATUS     current
	DESCRIPTION
		"First stack port for each unit. It returns 0 if stack port does not exist."
	::= { snStackingConfigUnitEntry 7 }


 snStackingConfigUnitStackPort2 OBJECT-TYPE
	SYNTAX		InterfaceIndexOrZero
	MAX-ACCESS read-only
	STATUS     current
	DESCRIPTION
		"Second stack port for each unit. It returns 0 if stack port does not exist."
	::= { snStackingConfigUnitEntry 8 }

 snStackingConfigUnitConnectPort1 OBJECT-TYPE
	SYNTAX		InterfaceIndexOrZero
	MAX-ACCESS read-write
	STATUS     current
	DESCRIPTION
		"First connect port for a peripheral unit in a mixed stacking system.  A peripheral
		unit can have up to two connect ports that is is conected to. They are suggested
		neighbor linking ports. Thus, they could be code units' periport/trunk or peripheral 
		units' stacking port. It returns 0 if connect port does not exist."
	::= { snStackingConfigUnitEntry 9 }

 snStackingConfigUnitConnectPort2 OBJECT-TYPE
	SYNTAX		InterfaceIndexOrZero
	MAX-ACCESS read-write
	STATUS     current
	DESCRIPTION
		"second connect port for a peripheral unit in a mixed stacking system.  A peripheral
		unit can have up to two connect ports that is is conected to. They are suggested
		neighbor linking ports. Thus, they could be code units' periport/trunk or peripheral 
		units' stacking port. It returns 0 if connect port does not exist."
	::= { snStackingConfigUnitEntry 10 }

--
-- Stacking operation unit Table
-- Use this table to display stacking related information for each operational unit
--

snStackingOperUnitTable OBJECT-TYPE
	SYNTAX     SEQUENCE OF SnStackingOperUnitEntry
	MAX-ACCESS not-accessible
	STATUS     current
	DESCRIPTION
		"Stacking operation unit table."
	::= { snStackingTableObjects 2 }

snStackingOperUnitEntry OBJECT-TYPE
	SYNTAX     SnStackingOperUnitEntry
	MAX-ACCESS not-accessible
	STATUS     current
	DESCRIPTION
		"An entry in the stacking operation table."
	INDEX { snStackingOperUnitIndex }
	::= { snStackingOperUnitTable 1 }

SnStackingOperUnitEntry ::= SEQUENCE {
	snStackingOperUnitIndex                    Integer32,
	snStackingOperUnitRole                     INTEGER,
	snStackingOperUnitMac                      MacAddress,
	snStackingOperUnitPriority                 Integer32,
	snStackingOperUnitState                    INTEGER,
	snStackingOperUnitDescription            DisplayString,
	snStackingOperUnitStackPort1            InterfaceIndexOrZero,
	snStackingOperUnitStackPort1State     INTEGER,
	snStackingOperUnitStackPort2            InterfaceIndexOrZero,
	snStackingOperUnitStackPort2State     INTEGER,
	snStackingOperUnitNeighbor1             Integer32,
	snStackingOperUnitNeighbor2             Integer32,
	snStackingOperUnitImgVer                 DisplayString,
	snStackingOperUnitBuildlVer               DisplayString

}

snStackingOperUnitIndex OBJECT-TYPE
	SYNTAX     Integer32
	MAX-ACCESS not-accessible
	STATUS     current
	DESCRIPTION
		"The stacking unit Id"
	::= { snStackingOperUnitEntry 1 }

 snStackingOperUnitRole OBJECT-TYPE
	SYNTAX     INTEGER {
			  other(1),
				 active(2),
				 standby(3),
				 member(4),
				 standalone(5)
			   }
	MAX-ACCESS read-only
	STATUS     current
	DESCRIPTION
		"A role for each unit "
	::= { snStackingOperUnitEntry 2 }

snStackingOperUnitMac OBJECT-TYPE
	SYNTAX     MacAddress
	MAX-ACCESS read-only
	STATUS     current
	DESCRIPTION
		"A MAC address for each unit"
	::= { snStackingOperUnitEntry 3 }

snStackingOperUnitPriority OBJECT-TYPE
	SYNTAX     Integer32 (0..255)
	MAX-ACCESS read-only
	STATUS     current
	DESCRIPTION
		"The priority in Active/backup eclection."
	::= { snStackingOperUnitEntry 4 }

 snStackingOperUnitState OBJECT-TYPE
	SYNTAX     INTEGER {
				 local(1),
				 remote(2),
				 reserved(3),
				 empty(4)
			   }
	MAX-ACCESS read-only
	STATUS     current
	DESCRIPTION
		"A state for each unit "
	::= { snStackingOperUnitEntry 5}

 snStackingOperUnitDescription OBJECT-TYPE
	SYNTAX		DisplayString (SIZE (0..128))
	MAX-ACCESS read-only
	STATUS     current
	DESCRIPTION
		"Describes the stacking state for each unit."
	::= { snStackingOperUnitEntry 6 }

 snStackingOperUnitStackPort1 OBJECT-TYPE
	SYNTAX		InterfaceIndexOrZero
	MAX-ACCESS read-only
	STATUS     current
	DESCRIPTION
		"First stack port for each unit. It returns 0 if stack port does not exist."
	::= { snStackingOperUnitEntry 7 }

 snStackingOperUnitStackPort1State OBJECT-TYPE
	SYNTAX     INTEGER {
		other(1),
		up(2),
		down(3)
	}
	MAX-ACCESS read-only
	STATUS     current
	DESCRIPTION
		"The first stack port state for each unit. "
	::= { snStackingOperUnitEntry 8 }


 snStackingOperUnitStackPort2 OBJECT-TYPE
	SYNTAX		InterfaceIndexOrZero
	MAX-ACCESS read-only
	STATUS     current
	DESCRIPTION
		"Second stack port for each unit. It returns 0 if stack port does not exist."
	::= { snStackingOperUnitEntry 9 }

 snStackingOperUnitStackPort2State OBJECT-TYPE
	SYNTAX     INTEGER {
		other(1),
		up(2),
		down(3)
	}
	MAX-ACCESS read-only
	STATUS     current
	DESCRIPTION
		"The second stack port state for each unit. "
	::= { snStackingOperUnitEntry 10 }

 snStackingOperUnitNeighbor1 OBJECT-TYPE
	SYNTAX		 Integer32
	MAX-ACCESS read-only
	STATUS     current
	DESCRIPTION
	"Stacking neighbor unit (left) number.
	If there is no neighbor unit, then it returns 0."

	::= { snStackingOperUnitEntry 11 }

 snStackingOperUnitNeighbor2 OBJECT-TYPE
	SYNTAX		Integer32
	MAX-ACCESS read-only
	STATUS     current
	DESCRIPTION
	"Stacking neighbor unit (left) number.
	If there is no neighbor unit, then it returns 0."
	::= { snStackingOperUnitEntry 12 }

snStackingOperUnitImgVer OBJECT-TYPE
	SYNTAX		DisplayString (SIZE (0..32))
	MAX-ACCESS read-only
	STATUS     current
	DESCRIPTION
		"The version of the running software image"
	::= { snStackingOperUnitEntry 13 }

snStackingOperUnitBuildlVer OBJECT-TYPE
	SYNTAX		DisplayString (SIZE (0..32))
	MAX-ACCESS read-only
	STATUS     current
	DESCRIPTION
		"The version of the running software build"
	::= { snStackingOperUnitEntry 14 }

--
-- Stacking configuration stack trunk Table
-- Use this table to display and configure stack trunks for each unit
--

snStackingConfigStackTrunkTable OBJECT-TYPE
	SYNTAX     SEQUENCE OF SnStackingConfigStackTrunkEntry
	MAX-ACCESS not-accessible
	STATUS     current
	DESCRIPTION
		"Stacking configuration stack trunk table."
	::= { snStackingTableObjects 3 }

snStackingConfigStackTrunkEntry OBJECT-TYPE
	SYNTAX     SnStackingConfigStackTrunkEntry
	MAX-ACCESS not-accessible
	STATUS     current
	DESCRIPTION
		"An entry in the stacking configuration Stack trunk table."
	INDEX { snStackingConfigStackTrunkUnit, snStackingConfigStackTrunkPort1,
	             snStackingConfigStackTrunkPort2 }
	::= { snStackingConfigStackTrunkTable 1 }

SnStackingConfigStackTrunkEntry ::= SEQUENCE {
	snStackingConfigStackTrunkUnit                   Integer32,
	snStackingConfigStackTrunkPort1                 InterfaceIndexOrZero,
	snStackingConfigStackTrunkPort2                 InterfaceIndexOrZero,
	snStackingConfigStackTrunkRowStatus        INTEGER,
 	snStackingConfigStackTrunkNumPort1          Integer32,
 	snStackingConfigStackTrunkNumPort2          Integer32
}

snStackingConfigStackTrunkUnit OBJECT-TYPE
	SYNTAX Integer32
	MAX-ACCESS not-accessible
	STATUS     current
	DESCRIPTION
		"The stacking unit Id"
	::= { snStackingConfigStackTrunkEntry 1 }

 snStackingConfigStackTrunkPort1 OBJECT-TYPE
	SYNTAX		InterfaceIndexOrZero
	MAX-ACCESS  not-accessible
	STATUS     current
	DESCRIPTION
		"The IfIndex for the first (primary) port of the configured stack trunk. 
		There are two ports per stack trunk. In some case, a physical port may contain 
		more than one port, e.g. one 40G (1/2/2) for ICX6610 has 4x10G ports. 
		It returns 0 if the port does not exist." 
	::= { snStackingConfigStackTrunkEntry 2 }

 snStackingConfigStackTrunkPort2 OBJECT-TYPE
	SYNTAX		InterfaceIndexOrZero
	MAX-ACCESS  not-accessible
	STATUS     current
	DESCRIPTION
		"The IfIndex for the second port of the configured stack trunk. 
		There are two ports per stack trunk. In some case, a physical port may contain 
		more than one logical port, e.g. one 40G (1/2/2) for ICX6610 has 4x10G ports. 
		It returns 0 if the port does not exist." 
	::= { snStackingConfigStackTrunkEntry 3 }

snStackingConfigStackTrunkRowStatus OBJECT-TYPE
	SYNTAX     INTEGER {
				 other(1),
				 valid(2),
				 delete(3),
		                 create(4)
			   }
	MAX-ACCESS read-write
	STATUS     current
	DESCRIPTION
			"This object is used to delete row in the
			table and control if they are used. The values that
			can be written are:
			delete(3)...deletes the row

			If the row exists, then a SET with value of create(4)
			returns error 'wrongValue'. Deleted rows go away immediately.
			The following values can be returned on reads:
			noSuchName...no such row
			other(1).....some other cases
			valid(2)....the row exists and is valid"
	::= { snStackingConfigStackTrunkEntry 4 }

 snStackingConfigStackTrunkNumPort1 OBJECT-TYPE
	SYNTAX		Integer32
	MAX-ACCESS  read-only
	STATUS     current
	DESCRIPTION
		" Number of logical ports for the first (primary) port of the configured stack trunk. 
		In some case, a physical port may contain more than one logical port, 
		e.g. one 40G (1/2/2) for ICX6610 has 4x10G ports.  It returns 0 if the port 
		does not exist." 
	::= { snStackingConfigStackTrunkEntry 5 }

 snStackingConfigStackTrunkNumPort2 OBJECT-TYPE
	SYNTAX		Integer32
	MAX-ACCESS  read-only
	STATUS     current
	DESCRIPTION
		" Number of logical ports for the second port of the configured stack trunk. 
		In some case, a physical port may contain more than one logical port, 
		e.g. one 40G (1/2/2) for ICX6610 has 4x10G ports.  It returns 0 if the port 
		does not exist." 
	::= { snStackingConfigStackTrunkEntry 6 }

--
-- Stacking configuration peripheral port Table
-- Use this table to display and configure mixed stacking peripheral ports  for each unit
--

snStackingConfigPeriPortTable OBJECT-TYPE
	SYNTAX     SEQUENCE OF SnStackingConfigPeriPortEntry
	MAX-ACCESS not-accessible
	STATUS     current
	DESCRIPTION
		"Stacking configuration peripheral port table."
	::= { snStackingTableObjects 4 }

snStackingConfigPeriPortEntry OBJECT-TYPE
	SYNTAX     SnStackingConfigPeriPortEntry
	MAX-ACCESS not-accessible
	STATUS     current
	DESCRIPTION
		"An entry in the stacking configuration peripheral port table."
	INDEX { snStackingConfigPeriPortUnit, snStackingConfigPeriPortPort }
	::= { snStackingConfigPeriPortTable 1 }

SnStackingConfigPeriPortEntry ::= SEQUENCE {
	snStackingConfigPeriPortUnit                   Integer32,
	snStackingConfigPeriPortPort                  InterfaceIndexOrZero,
	snStackingConfigPeriPortRowStatus        INTEGER
}

snStackingConfigPeriPortUnit OBJECT-TYPE
	SYNTAX Integer32
	MAX-ACCESS not-accessible
	STATUS     current
	DESCRIPTION
		"The stacking unit Id"
	::= { snStackingConfigPeriPortEntry 1 }

 snStackingConfigPeriPortPort OBJECT-TYPE
	SYNTAX		InterfaceIndexOrZero
	MAX-ACCESS  not-accessible
	STATUS     current
	DESCRIPTION
		"The IfIndex for the configured mixed stacking peripheral port. 
		It is up to eight peripheral ports per unit. "
	::= { snStackingConfigPeriPortEntry 2 }

snStackingConfigPeriPortRowStatus OBJECT-TYPE
	SYNTAX     INTEGER {
				 other(1),
				 valid(2),
				 delete(3),
		                 create(4)
			   }
	MAX-ACCESS read-write
	STATUS     current
	DESCRIPTION
			"This object is used to delete row in the
			table and control if they are used. The values that
			can be written are:
			delete(3)...deletes the row

			If the row exists, then a SET with value of create(4)
			returns error 'wrongValue'. Deleted rows go away immediately.
			The following values can be returned on reads:
			noSuchName...no such row
			other(1).....some other cases
			valid(2)....the row exists and is valid"
	::= { snStackingConfigPeriPortEntry 3 }


--
-- Stacking configuration peripheral trunk Table
-- Use this table to display and configure mixed stacking peripheral trunks  for each unit
--

snStackingConfigPeriTrunkTable OBJECT-TYPE
	SYNTAX     SEQUENCE OF SnStackingConfigPeriTrunkEntry
	MAX-ACCESS not-accessible
	STATUS     current
	DESCRIPTION
		"Stacking configuration peripheral trunk table."
	::= { snStackingTableObjects 5 }

snStackingConfigPeriTrunkEntry OBJECT-TYPE
	SYNTAX     SnStackingConfigPeriTrunkEntry
	MAX-ACCESS not-accessible
	STATUS     current
	DESCRIPTION
		"An entry in the stacking configuration peripheral trunk table."
	INDEX { snStackingConfigPeriTrunkUnit, snStackingConfigPeriTrunkPort1,
	             snStackingConfigPeriTrunkPort2 }
	::= { snStackingConfigPeriTrunkTable 1 }

SnStackingConfigPeriTrunkEntry ::= SEQUENCE {
	snStackingConfigPeriTrunkUnit                   Integer32,
	snStackingConfigPeriTrunkPort1                 InterfaceIndexOrZero,
	snStackingConfigPeriTrunkPort2                 InterfaceIndexOrZero,
	snStackingConfigPeriTrunkRowStatus        INTEGER
}

snStackingConfigPeriTrunkUnit OBJECT-TYPE
	SYNTAX Integer32
	MAX-ACCESS not-accessible
	STATUS     current
	DESCRIPTION
		"The stacking unit Id"
	::= { snStackingConfigPeriTrunkEntry 1 }

 snStackingConfigPeriTrunkPort1 OBJECT-TYPE
	SYNTAX		InterfaceIndexOrZero
	MAX-ACCESS  not-accessible
	STATUS     current
	DESCRIPTION
		"The IfIndex for the first port of the configured mixed stacking peripheral trunk. 
		There are two ports per peripheral trunk. It is up to four peripheral trunks per unit." 
	::= { snStackingConfigPeriTrunkEntry 2 }

 snStackingConfigPeriTrunkPort2 OBJECT-TYPE
	SYNTAX		InterfaceIndexOrZero
	MAX-ACCESS  not-accessible
	STATUS     current
	DESCRIPTION
		"The IfIndex for the second port of the configured mixed stacking peripheral trunk. 
		There are two ports per peripheral trunk. It is up to four peripheral trunks per unit." 
	::= { snStackingConfigPeriTrunkEntry 3 }

snStackingConfigPeriTrunkRowStatus OBJECT-TYPE
	SYNTAX     INTEGER {
				 other(1),
				 valid(2),
				 delete(3),
		                 create(4)
			   }
	MAX-ACCESS read-write
	STATUS     current
	DESCRIPTION
			"This object is used to delete row in the
			table and control if they are used. The values that
			can be written are:
			delete(3)...deletes the row

			If the row exists, then a SET with value of create(4)
			returns error 'wrongValue'. Deleted rows go away immediately.
			The following values can be returned on reads:
			noSuchName...no such row
			other(1).....some other cases
			valid(2)....the row exists and is valid"
	::= { snStackingConfigPeriTrunkEntry 4 }

--
-- Stacking neighbor port Table
-- Use this table to display stacking neighbor ports  for each unit
--

snStackingNeighborPortTable OBJECT-TYPE
	SYNTAX     SEQUENCE OF SnStackingNeighborPortEntry
	MAX-ACCESS not-accessible
	STATUS     current
	DESCRIPTION
		"Stacking neighbor port table."
	::= { snStackingTableObjects 6 }

snStackingNeighborPortEntry OBJECT-TYPE
	SYNTAX     SnStackingNeighborPortEntry
	MAX-ACCESS not-accessible
	STATUS     current
	DESCRIPTION
		"An entry in the stacking neighborport table."
	INDEX { snStackingNeighborPortUnit, snStackingNeighborPortStackPort }
	::= { snStackingNeighborPortTable 1 }

SnStackingNeighborPortEntry ::= SEQUENCE {
	snStackingNeighborPortUnit                   Integer32,
	snStackingNeighborPortStackPort                  InterfaceIndexOrZero,
	snStackingNeighborPortNeighborPort                  InterfaceIndexOrZero
}

snStackingNeighborPortUnit OBJECT-TYPE
	SYNTAX Integer32
	MAX-ACCESS not-accessible
	STATUS     current
	DESCRIPTION
		"The stacking unit Id"
	::= { snStackingNeighborPortEntry 1 }

 snStackingNeighborPortStackPort OBJECT-TYPE
	SYNTAX		InterfaceIndexOrZero
	MAX-ACCESS  not-accessible
	STATUS     current
	DESCRIPTION
		"The IfIndex for the stack port on this unit. 
		It is up to ten stack ports and peripheral ports per unit. "
	::= { snStackingNeighborPortEntry 2 }

 snStackingNeighborPortNeighborPort OBJECT-TYPE
	SYNTAX		InterfaceIndexOrZero
	MAX-ACCESS  read-only
	STATUS     current
	DESCRIPTION
		"The IfIndex for the neighbor port of  the stack port on this unit. 
		It returns 0 if neighbor port does not exist for this stack port. "
	::= { snStackingNeighborPortEntry 3 }

END